A steam table lists the thermodynamic properties of water and steam (temperature, pressure, volume, energy, enthalpy and entropy) at specific conditions. Once you know which table to open and what each column means, reading one takes less than a minute. This guide walks through the whole process with worked examples in both SI and US customary units.
What a steam table is and why engineers still use it
Water doesn’t behave like an ideal gas, so you can’t calculate its properties with a simple formula like PV = mRT. Instead, its properties are measured, fitted to complex equations, and tabulated. The current international standard for engineering work is IAPWS-IF97, the Industrial Formulation published by the International Association for the Properties of Water and Steam.
Engineers use steam tables to:
- Find the energy carried by steam in a header or pipe
- Calculate turbine work, boiler heat input and cycle efficiency
- Size heat exchangers, steam traps, flash tanks and piping
- Check whether steam is wet, saturated or superheated
Even if you use software day to day, knowing how to read the tables lets you sanity-check results and solve problems in exams, where software usually isn’t allowed.
The three table types: saturated, superheated, compressed liquid
Most steam table books contain three kinds of table. Choosing the right one is the first step in every problem.
| Table | Use it when | You need to know |
|---|---|---|
| Saturated (by temperature or by pressure) | Water is boiling or condensing: liquid and vapor coexist | Pressure or temperature (one is enough) |
| Superheated vapor | Steam is hotter than the boiling point at its pressure | Pressure and temperature |
| Compressed (subcooled) liquid | Water is colder than the boiling point at its pressure | Pressure and temperature |
How to decide: look up the saturation temperature (Tsat) at your pressure.
- Your temperature equals Tsat → saturated table
- Your temperature is above Tsat → superheated table
- Your temperature is below Tsat → compressed liquid table
At saturation, pressure and temperature are locked together. Water at 1 atm boils at about 100 °C, and at 1 MPa it boils at 179.89 °C. That’s why the saturated table needs only one of the two, while the other tables need both.
The saturated table comes in two versions that contain the same data: one with temperature in the first column, one with pressure. Use whichever matches the value you know, so you don’t have to interpolate.
Columns explained: P, T, v, u, h, s, and the f / g / fg subscripts
| Symbol | Property | SI units | US units |
|---|---|---|---|
| P | Absolute pressure | kPa or MPa | psia |
| T | Temperature | °C | °F |
| v | Specific volume | m³/kg | ft³/lb |
| u | Specific internal energy | kJ/kg | Btu/lb |
| h | Specific enthalpy | kJ/kg | Btu/lb |
| s | Specific entropy | kJ/(kg·K) | Btu/(lb·°R) |
In the saturated tables, each property appears with a subscript:
- f (often said to come from the German flüssig, liquid): saturated liquid, water at its boiling point that hasn’t started to evaporate yet
- g (gas): saturated vapor, also called dry saturated steam
- fg: the difference between the two, g − f. For enthalpy, hfg is the latent heat of vaporization, the energy needed to turn 1 kg (or 1 lb) of boiling water into steam.
So hg = hf + hfg. Many tables print all three so you don’t have to add them yourself.
A note on “specific”: every property is per unit mass. To get totals, multiply by the mass or mass flow. For example, enthalpy in kJ/kg times flow in kg/s gives energy flow in kW.
Example 1: find hg at a given pressure
Problem (SI): Dry saturated steam is at 1 MPa (10 bar absolute). Find its temperature, specific volume and enthalpy.
Step 1: pick the table. The steam is saturated, and we know its pressure, so use the saturated table by pressure.
Step 2: find the row. Go down the pressure column to 1.0 MPa:
| P (MPa) | Tsat (°C) | vf (m³/kg) | vg (m³/kg) | hf (kJ/kg) | hfg (kJ/kg) | hg (kJ/kg) | sf | sg |
|---|---|---|---|---|---|---|---|---|
| 1.0 | 179.89 | 0.001127 | 0.19435 | 762.68 | 2014.44 | 2777.12 | 2.1384 | 6.5850 |
Step 3: read the answers. Dry saturated steam uses the g columns:
- T = 179.89 °C
- v = vg = 0.19435 m³/kg
- h = hg = 2777.12 kJ/kg
Notice how much bigger vg is than vf: the steam takes up about 170 times the volume of the water it came from. That’s why steam lines are so much larger than condensate lines.
Same problem in US units: saturated steam at 100 psia.
| P (psia) | Tsat (°F) | vf (ft³/lb) | vg (ft³/lb) | hf (Btu/lb) | hfg (Btu/lb) | hg (Btu/lb) |
|---|---|---|---|---|---|---|
| 100 | 327.82 | 0.01774 | 4.432 | 298.57 | 888.92 | 1187.49 |
So T = 327.82 °F and hg = 1187.49 Btu/lb.
What if the steam is wet?
Real steam often carries some water droplets. The quality, x, is the fraction of the mixture by mass that is vapor: x = 1 is dry saturated steam, x = 0 is saturated liquid. Any property of the mixture is:
h = hf + x · hfg
For 1 MPa steam at 90% quality: h = 762.68 + 0.90 × 2014.44 = 2575.68 kJ/kg, about 200 kJ/kg less than dry steam. The same formula works for v, u and s. See steam quality and how to calculate it for more.
Example 2: superheated steam at a given P and T
Problem (SI): Steam is at 1 MPa and 300 °C. Find its specific volume, enthalpy and entropy.
Step 1: pick the table. From Example 1, Tsat at 1 MPa is 179.89 °C. Our 300 °C is higher, so the steam is superheated by about 120 °C. Use the superheated table.
Step 2: find the block. Superheated tables are arranged in blocks, one for each pressure, with temperature down the side. Find the 1 MPa block. Many books print Tsat in parentheses next to the pressure as a reminder.
Step 3: find the row and read.
| T (°C) | v (m³/kg) | u (kJ/kg) | h (kJ/kg) | s (kJ/(kg·K)) |
|---|---|---|---|---|
| 300 | 0.25798 | 2793.72 | 3051.70 | 7.1247 |
So v = 0.25798 m³/kg, h = 3051.70 kJ/kg, s = 7.1247 kJ/(kg·K).
Compare this to Example 1: at the same pressure, superheating from 179.89 °C to 300 °C adds about 275 kJ/kg of enthalpy and increases the volume by about a third.
Same idea in US units: at 100 psia and 500 °F (superheated, since Tsat is 327.82 °F), the 100 psia block gives v = 5.588 ft³/lb, h = 1279.32 Btu/lb and s = 1.7089 Btu/(lb·°R).
When your pressure or temperature isn’t in the table, you have to interpolate between the rows or blocks on either side. That’s covered step by step in linear interpolation in steam tables.
Common mistakes (gauge vs. absolute, wrong table, units)
1. Using gauge pressure. Steam tables use absolute pressure. A plant gauge reading 100 psig is really about 114.7 psia at sea level. Look up 100 psia instead and you’ll get a saturation temperature of 327.82 °F instead of 337.88 °F, about 10 °F off. Always add atmospheric pressure first. For more, see gauge vs. absolute pressure.
2. Using the wrong table. If you look up superheated values for a state that’s actually wet, or saturated values for superheated steam, your answer will be wrong with no warning. Always compare your temperature to Tsat first.
3. Mixing units. kPa and MPa differ by a factor of 1000, and bar is 100 kPa. Check the column header before you read a number.
4. Mixing tables from different sources. Absolute values of h, u and s depend on the reference state each table uses. Modern tables set u and s to zero for saturated liquid at the triple point (0.01 °C), but older books may differ. Differences between two states still come out right, but don’t combine values from two different books in one calculation.
5. Interpolating across the saturation line. Linear interpolation only works between two points in the same phase. Interpolating between a liquid row and a vapor row gives nonsense.
Download the printable tables
Want the tables at your desk? Download our free printable saturated steam tables (by temperature and by pressure, SI and US units), computed from IAPWS-IF97. You can also view the saturated steam table by temperature online.
Next: interpolation, steam quality
You can now find the right table and read properties for saturated, wet and superheated steam. Next steps:
- Saturated vs. superheated vs. compressed liquid tables: more on telling which region you’re in
- Steam quality (dryness fraction): working with wet steam
- Linear interpolation in steam tables: when your value falls between rows
- The Rankine cycle: a worked example: putting it all together
If you look up steam properties often, interpolation gets tedious and error-prone fast. SteamSolver gives exact IAPWS-IF97 values for any state from any two known properties, in SI or US units, with no interpolation.